Digital Automatic Leak Test Apparatus VLT A Specification

  • Operating Temperature
  • 10°C to 50°C
  • Test Range
  • 0 - 999 seconds (Timer setting)
  • Response Time
  • <1 second
  • Humidity
  • Up to 85% RH
  • Number of Specimens
  • 1
  • Test Material
  • Tablets, Strips, Blisters, Sachets, etc.
  • Accuracy
  • ± 1% of reading
  • Sensor
  • Pressure sensor (built-in)
  • Temperature
  • Ambient
  • Specimen Size
  • Max up to 150 mm diameter
  • Display
  • Large digital LED display
  • Power Supply
  • 230 V AC, 50 Hz
  • Gas Pressure
  • 0 to 600 mm of Hg
  • Type
  • Digital Automatic Leak Test Apparatus
  • Use
  • Leakage testing of pharmaceutical and packaging materials
  • Test Medium
  • Air (Dry, clean, and oil-free)
  • Operating Voltage
  • 230 V AC, 50 Hz
  • Shell Material
  • Mild Steel (Powder Coated)
  • Net Weight
  • 18 kg
  • Pedestal Size
  • 150 mm x 200 mm
  • Port Size
  • 10 mm
  • Operating Mode
  • Automatic
  • Chamber Volume
  • 4 liters
  • Vacuum Gauge
  • Analog vacuum gauge for real-time indication
  • Controls
  • Soft touch key controls
  • Data Logging
  • Manual entry (no internal memory)
  • Protection
  • Overload and short-circuit protected
  • Regulator
  • Vacuum regulator with fine adjustment
  • Alarm System
  • Audio and Visual end-of-test alarms
  • Vacuum Release
  • Automatic and manual modes
  • Compliance
  • Meets USP, IP, BP standards
 

Digital Automatic Leak Test Apparatus VLT A Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 1 Unit Per Month
  • Delivery Time
  • 6 Days
  • Sample Available
  • No
 

About Digital Automatic Leak Test Apparatus VLT A

LEAK TEST APPARATUS equipped with MICRO CONTROLLER based circuitry to ensure the leakages of sealed blisters, bottles and sachets during packing operation. Complete Automatic System.


  • Automatic system
  • Vacuum level can be set as per requirement
  • Display indicates actual vacuum level
  • Settable retention time, start delay time and vacuum hold time

Technical Details 



Precise Leak Testing for Pharmaceuticals

This apparatus is specially designed to test the integrity of pharmaceutical packaging like tablets, strips, blisters, and sachets. With a chamber volume of 4 liters and a built-in pressure sensor, it guarantees accurate test results. The automatic mode streamlines workflows, while the manual vacuum release offers flexibility during testing, ensuring operators get reliable outcomes every time.


Efficient Operation and Smart Controls

Convenient soft touch key controls simplify use, and real-time test readings are displayed on a large digital LED screen. The system incorporates automatic and manual vacuum release features, audio-visual alarms when each test concludes, and is safeguarded against overload and short-circuit incidents for worry-free, continuous operation.


Compliance and Durability You Can Trust

Robust construction using powder-coated mild steel ensures longevity, even in demanding lab environments. The apparatus complies with major standards such as USP, IP, and BP, making it suitable for regulated pharmaceutical use, and ensures peace of mind regarding data integrity and device safety.

FAQs of Digital Automatic Leak Test Apparatus VLT A:


Q: How does the Digital Automatic Leak Test Apparatus VLT A perform leak testing on pharmaceutical packages?

A: It subjects specimens like tablets, blister packs, and sachets to a controlled vacuum within its 4-liter chamber. A built-in pressure sensor detects variations, signaling leaks. Results are displayed on the LED screen and end-of-test audio-visual alarms notify the operator.

Q: What types of materials can be tested using this apparatus?

A: The apparatus accommodates a range of packaging materials including tablets, strips, blisters, and sachets, with specimens up to 150 mm in diameter, making it versatile for various pharmaceutical applications.

Q: When should I use automatic versus manual vacuum release?

A: Use automatic vacuum release for routine, standardized leak tests to streamline workflow and consistency. Manual mode is ideal when performing custom or exploratory tests where specific control over vacuum release is needed.

Q: Where is the Digital Automatic Leak Test Apparatus VLT A typically installed?

A: It is commonly installed in pharmaceutical laboratories, quality control departments, and manufacturing facilities where package integrity testing according to USP, IP, and BP standards is required.

Q: What is the process for logging test data with this device?

A: All data must be manually entered during or after testing, as the apparatus does not have internal memory for storage. This ensures documentation aligns with regulatory compliance but requires operator diligence.

Q: How does the alarm system benefit the operator during testing?

A: The integrated audio and visual alarms provide immediate notification at the conclusion of each test, allowing operators to stay focused without constantly monitoring the device, thus reducing oversight and improving efficiency.

Q: What are the key benefits of using this leak test apparatus?

A: Key benefits include high accuracy (1% of reading), rapid response time (<1 second), compliance with regulatory standards, efficient operation via digital controls, robust protection features, and suitability for a wide range of pharmaceutical packaging types.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Leak Test Apparatus Category

Digital Automatic Leak Test Apparatus Vlt Adv

Digital Automatic Leak Test Apparatus Vlt Adv

Price Range 93000.00 - 75000.00 / Unit

Minimum Order Quantity : 1 Unit

Type : Electronic

Dimension (L*W*H) : 480 Millimeter (mm)

Test Range : Vacuum level upto 600mm Hg

Advanced CFR Leak Test Apparatus - VLT-AD (CFT)

Advanced CFR Leak Test Apparatus - VLT-AD (CFT)

Price 1000.0 INR / Piece